跳至主要内容

How to Configure WiFi and USB for Original JLR DoIP VCI

 

Part 1: How to Configure WiFi for Original JLR DoIP VCI /setup wireless connection?

Original Jaguar Land Rover diagnostic tool JLR DoiP VCI supports both USB and WiFi connection. Here’s the guide to configure the LAN setting.

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-1 (2)

Procedure:

Connect JLR DoiP VCI W-F interface with vehicle

Connect the other end of VCI with laptop via USB cable

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-2 (2)

Open VCI Manager (JLR), press Connect

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-3 (2)

Choose Network Setup tab->Wired Etherent

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-4 (2)
Tick Enable Wired Etherent Interface

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-5 (2)

Press Apply button and Yes

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-6 (2)

Then disconnect USB connection

Close VCI Manager

Open VCI Manager again

Press Connect

Go to Network Setup->Wired Etherent

Press Set Factory Default

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-7 (2)

Press OK if system prompts you are about to reset the VCI communication settings to a factory default state.

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-8 (2)

Enable network connection

Press Set Factory Default again

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-9 (2)

In Wireless (802.11), choose Obtain an IP address automatically, then press Access Point

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-10 (2)

Choose Wireless resource which is the same as the your network
Press Configure

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-11 (2)

Enter wireless security password (encryption key)

Press Next

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-12 (2)

JLR VCI is configured to connect to your network

Disconnect and then Connect VCI

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-13 (2)

It shows WiFi connection is done

Open JLR SDD software on desktop

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-14 (2)

Press Connect

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-15 (2)
Now you can run SDD software for diagnosis

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-16 (2)

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-17 (2)
Part 2: How to connect JLR DoIP VCI via USB

To setup USB connection, you need to download Bosch driver for VCI first:

https://mega.nz/#!aqwnhbQS!KS7QhERmZ4cCcZfvT2iXkdYN6ynz9vDQ3DmPQRGm0TU

Open Bosch_Driver folder

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-18 (2)
Open MTS6533_Setup

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-19 (2)
Install Bosch VCI Software (JLR)
Press Next
Press Next
Press Install
Finish installing Bosch VCI software

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-20 (2)
USB Configuration in progress. Don’t disconnect JLR VCI from PC until a message indicates that the configuration process has completed.

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-21 (2)

Open Device Manager to check the Bosch JLR DoIP VCI adapter is well connected

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-22 (2)

Open VCI Manager on desktop to make sure the Manager detect JLR VCI which indicates interface is well connected

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-23 (2)

Right click JLR SDD software on desktop->Find File location C:/Program Files/JLR/SDD/Runtime

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-24 (2)

Open the GatewayManager with Notepad
Find “Device5 = JLR-DOIP” and change value to “,  Device5 = JLR-DOIP”

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-25 (2)

Find Go to C:/Program Files/JLR/IDS/Runtime

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-26 (2)
Open the GatewayManager with Notepad
Find “Device5 = JLR-DOIP” and change value to “,  Device5 = JLR-DOIP”

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-27 (2)

Setup completed.

Now you can run JLR SDD and Pathfinder software

How-to-Configure-WiFi-and-USB-for-Original-JLR-DoIP-VCI-28 (2)


评论

此博客中的热门博文

How to Replace and Reprogram Chrysler FCM with DRB III

  SUBJECT: Replacing or reprogramming the Front Control Module (FCM) OVERVIEW: Erroneous Actuation of Horns, Headlamps, and Parking Lamps while vehicle is parked MODELS: 2001 – 2004 (RG) Chrysler Voyager (International Markets) 2001 – 2004 (RS) Town & Country/Caravan/Voyager SYMPTOM/CONDITION: While the vehicle is parked the customer may experience the horn sounding on and off, flashing the headlamps and the parking lamps as if the security alarm was actuated. The technician may find the vehicle is not equipped with Security Alarm system (sales code LSA). DIAGNOSIS: 1. Using a Scan Tool (DRBIII®) with the appropriate Diagnostic Procedures Manual, verify all engine systems are functioning as designed. If DTCs are present record them on the repair order and repair as necessary before proceeding further with this bulletin. 2. Determine the “Hardware Part #” of the FCM. Using the DRB III select: 3. DRBIII Standalone 4. 1998 – 2005 Diagnostics 5. All 6. Body In...

How to update BMW ICOM A2 or ICOM NEXT Firmware

  When using the latest ISTA D software to do BMW diagnosis, icom hareware can be detected, but the device doesn’t communicate with the vehicle,  can’t enter modules reading page, like below picture: What’s the solution? The firmware doesn’t match with the  latest ISTA sofware, firmware need to be updated. ICOM firmware update steps: 1. Need the latest updated file for ICOM firmware: 2.Charge ICOM hardware, connect the vehicle, use ISTA engineering sofware IToolRadar to detect the IP address of  ICOM hardware, see below picture, the IP address can be found as 169.254.92.38 3. Open Internet Explorer Input the IP address which is deteced above to the address bar: like http://169.254.92.38:60080 username: root password: NZY11502 4. Click “update firmware” after login 5. Follow below steps: 6. Need to wait seconds, and click  “yes” when below  page show up: 7. During ICOM firmware update, four light on ICOM are all read, need to wait...

How to update the firmware of ICOM NEXT A

Upgraded the new version of  BMW Diagnostic Software ISTA. When connected to the vehicle, click to start the vehicle to detect ICOM, but the State is Firmware. At this time, you need to upgrade the firmware of BMW ICOM Next ; ICOM NEXT A firmware upgrade steps 1. First, you need the firmware file of the new version of ICOM NEXT, the ICOM NEXT firmware file has a name with ICOM NEXT XXX, The two files xxx root xxx and xxx app xxx need to be upgraded. (Firmware version is different, the file name is different, but all versions of the firmware have the file name of ICOM_Nextxx) 2.ICOM NEXT A is connected to the car, usually the OBD interface of the car (the same method as the car diagnosis), open the diagnostic software ISTA, or use the software ITool Radar, you can detect the IP address of ICOM NEXT (IP address is automatically obtained), The IP address detected by the ISTA software is 169.254.192.155; 3.Open the IE browser, enter the IP address and port number of...